Wenming Luh

 

Wenming Luh

Technical Director, Cornell MRI Facility
G301 Martha Van Rensselaer Hall
Cornell MRI Facility
 
Phone: (607) 255-1906 Fax: (607) 255-2122
Email: wenmingluh@cornell.edu
View Cornell University Contact Info
 
Biographical Statement:

Dr. Luh is the Technical Director of the Cornell MRI Facility (CMRIF), a newly established joint venture of the Colleges of Human Ecology, Engineering, Arts and Sciences and Veterinary Medicine. Before coming to Cornell in 2012, he was a Staff Scientist in the Functional MRI Facility of the intramural research program at the National Institute of Mental Health, National Institutes of Health. Dr. Luh is an expert in establishing and maintaining the star-of-art MRI facility dedicated to innovative research and technical development. He is also an expert in functional MRI for experimental design and data acquisition.

Dr. Luh’s research focuses on developing new methods and improving current techniques in image acquisition and signal quality through hardware and software intervention using MRI and functional MRI. One particular area is in the development of Arterial Spin Labeling techniques to measure cerebral blood flow as a surrogate to tissue health and function. The applications include clinical diagnosis of neurovascular diseases and neuronal activation during both task and resting states.

Recent advancement in functional MRI data acquisition includes the development of multiple-echo image acquisition to objectively discern functional related signal change from physiological related noise perturbation. The approach shows promising results in substantially improving the data quality, especially for resting-state connectivity measurement against motion artifacts and physiological fluctuation.

 
Current Research Activities:

- Characterizing and improving arterial spin labeling techniques on magnetic field inhomogeneity and the applications to functional MRI studies

- Investigation the variation of cerebral blood flow measurement throughout the lifespan and physiological conditions

- Broadening the application of the multiple-echo technique to various functional MRI studies

 
Education:

B.S. – Electrophysics – National Chiao Tung University, Hsinchu, Taiwan

M.S. – Life Sciences – National Tsing Hua University, Hsinchu, Taiwan

Ph.D. – Biophysics – Medical College of Wisconsin, Milwaukee, Wisconsin

Postdoctoral fellow – Radiology – University of California at San Diego, La Jolla, California

 
Related Websites:

 http://mri.cornell.edu/

 
Administrative Responsibilities:

Technical Director – Cornell MRI Facility

 

 
Selected Publications:

Liu N, Kriegeskorte N, Mur M, Hadj-Bouziane F, Luh WM, Tootell RBH, Ungerleider LG. Intrinsic structure of visual exemplars and category representations in Macaque brain. J. Neurosci. 33, 11346-60 (2013).

Misaki M, Luh WM, Bandettini PA. The effect of spatial smoothing on fMRI decoding suggesting information of columnar-level organization in multiple spatial scales of BOLD response. J. Neurosci. Methods 212, 355-61 (2013).

Gonzalez-Castillo J, Duthie KN, Saad ZS, Chu C, Bandettini PA, Luh WM. Effects of image contrast on functional MRI image registration. Neuroimage 67, 163-74 (2013).

Misaki M, Luh WM, Bandettini PA. Accurate decoding of sub-TR timing differences in stimulations of sub-voxel regions from multi-voxel response patterns. Neuroimage 66, 623-33 (2013).

Luh WM, Talagala SL, Li TQ, Bandettini PA. Pseudo-continuous arterial spin labeling at 7T for human brain: estimation and correction for off-resonance effects using a Prescan. Magn. Reson. Med. 69, 402-10 (2013).

Hadj-Bouziane F, Liu N, Bell AH, Gothard KA, Luh WM, Tootell RBH, Murray EA, Ungerleider LG. Amygdala lesions disrupt modulation of fMRI activity evoked by facial expression in the monkey inferior temporal cortex. Proc. Natl. Acad. Sci. USA 109, E3640-8 (2012).

Kundu P, Inati S, Evans JW, Luh WM, Bandettini PA. Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI. Neuroimage 60, 1759-70 (2012).

Sarlls JE, Pierpaoli C, Talagala SL, Luh WM. Robust fat suppression at 3T in high-resolution diffusion-weighted single-shot EPI of the brain. Magn. Reson. Med. 66, 1658-1665 (2011).

Olulade O, Hu S, Gonzalez-Castillo J, Tamer GG Jr, Luh WM, Ulmer JL, Talavage TM. Assessment of temporal state-dependent interactions between auditory fMRI responses to desired and undesired acoustic sources. Hear. Res. 277, 67-77 (2011).

Hu S, Olulade O, Gonzalez-Castillo J, Santos J, Kim S, Tamer GG Jr, Luh WM, Talavage TM. Modeling hemodynamic responses in auditory cortex at 1.5 T using variable duration imaging acoustic noise. Neuroimage 49, 3027-38 (2010).

Hu S, Olulade O, Tamer GG Jr, Luh WM, Talavage TM. Signal fluctuations induced by non-T1-related confounds in variable TR fMRI experiments. J. Magn. Reson. Imaging 29, 1234-9 (2009).

Tamer GG Jr, Luh WM, Talavage TM. Characterizing response to elemental unit of acoustic imaging noise: an FMRI study. IEEE Trans. Biomed. Eng. 56, 1919-28 (2009).

Lim YM, Cho YW, Shamim S, Solomon J, Birn R, Luh WM, Gaillard WD, Ritzl EK, Theodore WH. Usefulness of pulsed arterial spin labeling MR imaging in mesial temporal lobe epilepsy. Epilepsy Res. 82, 183-9 (2008).

Obata T, Liu TT, Miller KL, Luh WM, Wong EC, Frank LR, Buxton RB. Discrepancies between BOLD and flow dynamics in primary and supplementary motor areas: application of the balloon model to the interpretation of BOLD transients. Neuroimage 21, 114-153 (2004).

Miller KL, Luh WM, Liu TT, Martinez A, Obata T, Wong EC, Frank LR, Buxton RB. Characterizing the perfusion response to stimuli of short duration. Human Brain Mapping 13, 1-12 (2001).

Wong EC, Liu TT, Luh WM, Frank LR, Buxton RB. A T1 and T2 Selective Method for improved SNR in CSF attenuated imaging: T2-FLAIR. Magn. Reson. Med. 45, 529-532 (2001).

Wong EC, Luh WM, Liu TT. Turbo ASL: arterial spin labeling with higher SNR and temporal resolution. Magn. Reson. Med. 44, 511-515 (2000).

Luh WM, Wong EC, Bandettini PA, Ward BD, Hyde JS. Comparison of simultaneously measured perfusion and BOLD signals increases during brain activation with T1-based tissue identification. Magn. Reson. Med. 44, 137-143 (2000).

Luh WM, Wong EC, Bandettini PA, Hyde JS. QUIPSS II with thin-slice TI1 periodic saturation: a method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling. Magn. Reson. Med. 41, 1246-1254 (1999).

Frank LR, Wong EC, Luh WM, Ahn JM, Resnick D. Articular cartilage in the knee: mapping of the physiologic parameters at MR imaging with a local gradient coil—preliminary results. Radiology 210, 241-246 (1999).

Donahue KM, Van Kylen J, Guven S, El-Bershawi A, Luh WM, Bandettini PA, Cox RW, Hyde JS, Kissebah AH. Simultaneous gradient-echo/spin-echo EPI of graded ischemia in human skeletal muscle. J. Magn. Reson. Imaging 8,1106-1113 (1998).

 

 
The information on this bio page is taken from the CHE Annual Report.